Introduction

The Dinger Doorstation supports remote lock control through either Josh.AI integration or the IC View Pro mobile application. It is compatible with two types of door locks: electric door strikes, which are the most commonly used, and electromagnetic locks. Wiring requirements vary depending on the lock type selected.

 

Electric Strike Wiring

The method used to power the lock is at your discretion; however, for the example below, an IC Realtime POWER-JACK is used to avoid cutting wires, which could potentially void the warranty on the electric strike or power supply.

01. Connect the Dinger Doorstation's green wire (Door NO) to the negative lead (typically black) of your power supply.

02. Connect the Dinger Doorstation's orange wire (Door COM) to the negative lead (typically black) to your electric door strike

03. Connect to the positive lead (typically red) from your power supply to the positive lead (typically red) of your electric door strike.

db20_electricStrike_connection_thumbnail.jpg
db20_electricStrike_connection_thumbnail_02.jpg

(Click the thumbnail to view the full-sized image)

 

Electromagnetic Lock Wiring

Once again, the method used to power the lock is at your discretion.

01. Connect the Dinger Doorstation's purple wire (Door NC) to the negative lead (typically black) of your electromagnetic lock.

02. Connect the Dinger Doorstation's orange wire (Door COM) to the negative lead (typically black) to your power supply.

03. Connect to the positive lead (typically red) from your power supply to the positive lead (typically red) of your electromagnetic lock.

db20_maglock_connection_thumbnail.jpg
db20_maglock_connection_thumbnail_02.jpg

(Click the thumbnail to view the full-sized image)

 

Configuring the Dinger Doorstation Access Control

After wiring your Dinger Doorstation to the lock style of your choice, it must now be configured. You may complete this by performing the following steps:

01. Log directly into the Dinger Doorstation using it's LAN IP address via the web browser of your choice.

02. Select "Access Config"

03. Click "Access Control", then choose Config

04. Set the following options

Interval between Consecutive Unlocks The lock can only be unlocked again after the configured interval has elapsed (1–20 seconds).
Door Unlocked Duration The duration for which the lock remains unlocked (1–20 seconds).
Alarm Input / Door Detector Set to "Alarm Input"
Unlock Code Leave blank
Lock Linkage Leave unchecked
access_config_options_thumbnail.jpg

(Click the thumbnail to view the full-sized image)

 

Using IC View Pro for Lock Control

Once the lock is wired and the Dinger Doorstation is configured you may now use IC View Pro to manually unlock the door using the following steps:

01. Open IC View Pro

02. Tap on the Dinger Doorstation preview to load the video feed

03. Tap the ↓↓ located below the screenshot & local record buttons to expand the menu

icvp_01_thumbnail.jpg

(Click the thumbnail to view the full-sized image)

04. Tap the padlock icon, then choose "Confirm" to engage the unlock function

icvp_02_thumbnail.jpg

(Click the thumbnail to view the full-sized image)

05. If successful a message will be displayed "Unlocked Successfully" within the mobile application. An audio announcement will also be played at the Dinger Doorstation stating "Successfully Unlocked". 

icvp_03_thumbnail.jpg

(Click the thumbnail to view the full-sized image)

Still stuck?

Our support team answers by email. It helps to have these ready:

Model numberSerial numberFirmware or app versionWhat you have tried